Description This example shows the operation of the Multilevel multiphase SVPWM and Two-level multiphase SVPWM. It includes a five-level five-phase inverter feeding a passive load. Detailed information about the modulation algorithm, its Simulink® implementation, and the simulated case can be found in [1]. Abstract: - This paper presents analysis, simulation and implementation of Space vector pulse width modulation (SVPWM) inverter. Principles of the SVPWM is introduced and analyzed. Across a technique called space vector pulse width modulation. [1,2] The most advantageous method among the PWM is space vector pulse width modulation, Where the inverter can be Fig. Two level voltage source inverter thought as three separate push pull drive stages and the inverter can be driven into eight unique steps[3]. Dear everybody! If you find this channel useful, please support the channel by sending money back to my paypal account [email protected] Thank you very much. The 'Sine Wave f' and 'Fifth harmonic' blocks generate an unbalanced five-phase reference voltage with a fifth harmonic. The 'Normalize' block normalize the reference voltage 3. The 'Multilevel multiphase SVPWM' performs the multilevel multiphase space-vector PWM (SVPWM) algorithm presented in [1]. This block makes use of the block 'Two-level multiphase SVPWM', also described in [1], that can be used alone with two-level multiphase converters. Both blocks require the specification of the number of phases and their outputs are a matrix with the switching vector sequence and a vector with the switching times. The 'Sequence' block provides the time sequence of switching vectors. The 'Trigger signals' generates the proper trigger signals from output levels specified in each switching vector. The '5-level 5-phase cascaded full-bridge inverter' block is the ideal model of the multilevel voltage-source converter. The loads are resistances with a series connected inductances. Load neutral is connected to the inverter neutral. Simulation The following signals can be observed: 'Vref' is the sampled voltage reference for each phase. 'filtered Vout' is the output voltage of 'Vout' phase after been filtered with a low-pass filter. 'Vout(k)' is the switched output voltage of phase 'k'. The phase shown in the scope can be selected by means of the 'Phase selection' block. The filtered output voltage 'filtered Vout' of the converter follows the reference voltage 'Vref'. Therefore, the modulation is working properly. The output voltage of the inverter 'Vout' has five levels in phases b, c, and d (k=2,3,4) and three levels in phase a and e (k=1,5). References [1] Oscar Lopez, Jacobo Alvarez, Jesus Doval-Gandoy and Francisco D. Freijedo 'Multilevel Multiphase Space Vector PWM algorithm', IEEE® Transactions on Industrial Electronics, vol. 1933-1942, May 2008, doi:10.1109/TIE.2008.918466. Description The Space Vector PWM VSI Induction Motor Drive block represents a classical closed-loop Volts/Hz control drive for induction motors. The block contains a closed-loop speed control with slip regulation. The speed-control loop outputs the reference motor slip, which is added to the measured rotor speed to obtain the reference frequency of the stator flux. The reference stator voltage is derived from the Volts/Hz control and from the constant flux strategy. The stator frequency and voltage references are then used to obtain the required PWM signals for the inverter following the space vector modulation strategy. The main advantage of this drive compared to vector-controlled drives is its implementation simplicity. However, as with most scalar-controlled drives, the dynamic response of this drive is slow due to the inherent coupling effect between the torque and flux present in the machine. • The speed controller sampling time • The space vector modulator controller sampling time The speed controller sampling time has to be a multiple of the space vector modulator sampling time. The latter sampling time has to be a multiple of the simulation time step. The simulation step size must be chosen in accordance with the inverter's switching frequency. A rule of thumb is to choose a simulation step size 100 times smaller than the switching period. If the simulation step size is set too high, the simulation results can be erroneous. ![]() ![]() The average-value inverter allows the use of bigger simulation time steps since it does not generate small time constants (due to the RC snubbers) inherent to the detailed converter. For a controller sampling time of 20 µs, good simulation results have been obtained for a simulation time step of 20 µs. This time step can, of course, not be higher than the controller time step. Output bus mode Select how the output variables are organized. How do i install a crib bumper. If you select Multiple output buses (default), the block has three separate output buses for motor, converter, and controller variables. If you select Single output bus, all variables output on a single bus. Model detail level Select between the detailed and the average-value inverter. Default is Detailed. Mechanical input Select between the load torque, the motor speed and the mechanical rotational port as mechanical input. Default is Torque Tm. If you select and apply a load torque, the output is the motor speed according to the following differential equation that describes the mechanical system dynamics. T e = J d d t ω r + F ω r + T m This mechanical system is included in the motor model. For the mechanical rotational port, the connection port S counts for the mechanical input and output. It allows a direct connection to the Simscape environment. The mechanical system of the motor is also included in the drive and is based on the same differential equation. If you select the motor speed as mechanical input, then you get the electromagnetic torque as output, allowing you to represent externally the mechanical system dynamics. The internal mechanical system is not used with this mechanical input selection and the inertia and viscous friction parameters are not displayed. Use signal names as labels When you select this check box, the Motor, Conv, and Ctrl measurement outputs use the signal names to identify the bus labels. Select this option for applications that require bus signal labels to have only alphanumeric characters. When this check box is cleared (default), the measurement output uses the signal definition to identify the bus labels. ![]() Tm or Wm The mechanical input: load torque (Tm) or motor speed (Wm). For the mechanical rotational port (S), this input is deleted. A, B, C The three phase terminals of the motor drive. Wm, Te or S The mechanical output: motor speed (Wm), electromagnetic torque (Te) or mechanical rotational port (S). When the Output bus mode parameter is set to Multiple output buses, the block has the following three output buses.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |